Advanced Searches

Empirical Signal Integrity Data

Final Inch® is not complete without validation of the electrical system performance through signal integrity modeling, simulations, and measurements.

Advanced 2D and 3D modeling methods are used to provide accurate models for all sections of the Final Inch® boards. Test boards have been manufactured and characterized through measurements and then correlated to simulations.

These measurements are then compared to original simulation results for correlation and modeling process improvement. Some VNA measurements are converted to HSPICE models utilizing Sigrity BroadBand Spice, simulated in the frequency and time domain, and compared to the original simulation models. These comparisons are fed back into the modeling process to correct for PCB trace loss characteristics and provide process improvements.

Samtec is now offering "on request" test data including eye patterns for our Final Inch® circuits using our new Agilent PLTS 50 GHz Characterization System. For more information on this new service, click here.

Click here to view Samtec's Comparison of Eye Patterns Generated by Synopsis HSPICE and the Agilent PLTS white paper. This document shows that there is good correlation between Samtec's Final Inch® HSPICE simulated eye patterns to eye patterns processed from S-parameter data measured with Samtec's new Agilent PLTS 50 GHz High Speed Characterization System. Samtec Q Pairs® QTE-DP/QSE-DP Final Inch® simulations were used as the test article.

For more information or questions about Final Inch®, email the Samtec Final Inch® Group or submit our Final Inch® Request Form.

NOTE: Samtec Final Inch® models are Intellectual Property protected by US and International copyrights. These designs and data are licensed for unlimited, free use by Samtec customers under certain conditions.

Click here to view a read-only copy of the terms and conditions of each applicable license agreement.